Home
 
 
 
 
1 | 2 | 3 | 4
 
Category: PLATES-FEMORAL OSTEOTOMY PLATES
-----------------------------------------------------------------------------------------------
 
Intertrochanteric Osteotomy Barrel Plate 110°, 120°, 130°.
Cat No. Holes
K144-01
K144-02
K144-03
04
05
06
Profile : thickness 5.4, width 16mm
Indication : Neglected fracture neck femur where Intertrochantric Osteotomy required.
Fixation : With 4.5mm Cortical screws, DHS instrument set not required DCS instrument set required.
----------------------------------------------------------------------------------------------------
Angled Blade Plate for Intertrochanteric OsteotomicsOsteotomics – 90° with DCP Holes
 
Angle Blade Plate for Intertrochantric Osteotomics m120° with DCP Holes
Cat No. Holes Length
K145-90-04 04 50mm
K145-90-04 04 60mm
Cat No. Holes Length
K146-120-04 04 65mm
K146-120-04 04 75mm
K146-120-04 04 85mm
Profile: Thickness 5.6 mm, width 16.0mm, hole spacing 16.0mm, overall height 94mm. Profile: Thickness 5.6 mm, width 16.0mm, hole spacing 16.0mm, DCP holes.
Indication:Neglected fractures neck femur , where intertrochanteric osteotomy required. Indication: :Repositioning Osteotomics in the treatment of Femoral neck fracture and Pseudoarthroses.
Fixation :With 4.5 mm Cortex screws  
----------------------------------------------------------------------------------------------------
Wainwright Plates
 
Kessel Plates
Cat No.
Holes
Length
Cat No.
Holes
K150-40 to 60-03
K150-40 to 60-04

03
04
40,45,50,60mm
40,45,50,60mm
K152-03
K152-04

03
04

Indication: : : For Mac-Murrey Osteotomy Indication: For Mac-Murrey Osteotome
Fixation :With 4.5 mm Cortical Screws. Fixation : With 4.5mm Cortical Screws.
----------------------------------------------------------------------------------------------------
Condylar Plate 90°.
Cat No. Holes  Length.
K158-50 to 80-05
K158-50 to 80-07
K158-50 to 80-09
K158-50 to 80-12
K158-50 to 80-14
K158-50 to 80-16



05
07
09
12
14
16

50,60,70,80mm
50,60,70,80mm
50,60,70,80mm
50,60,70,80mm
50,60,70,80mm
50,60,70,80mm
Profile :: Thickness 5.6mm, width 16.0m, hole spacing 16.0mm,.Autocompression holes, U-profile blade : 6.5 x 16.0mm.
Indication: : For fracture in distal and proximal femoral region as well as for Intertrochantric vulgus osteotomy.
Fixation :All hole with 4.5 cortical screw but proximal two holes next to the blade may be fixed with 6.5 cancellous screws.
----------------------------------------------------------------------------------------------------
Condylar Buttress Plate, s.s. for Right/ Left Femoral Condylars
Cat No. Holes 
K159-50 to 80 –07
K159-50 to 80 –09
K159-50 to 80 –12
K159-50 to 80 –14
K159-50 to 80 –16



07
09
11
13
15
 
Profile :: Thickness 5mm, width 16mm, hole spacing 16mm.
Indication:As buttress for femoral Condylar with multiple fractures fragments.
Fixation :With 4.5mm and 6.5 screws.


:: Our Other Products ::

       
 Instruments  :   -Bone Holding Clamps
-Bone Spreader
 
-Drills
 
-Handles - fibre handles for quickcoupling  
-Impactors - K - Nail Impactor 
-Plaster Spreader
-Reduction Forceps Pointed - SpeedLock 
-Screw Drivers
-WireTwisterCicular 
-Screw Set - Large 
-Instruments Set for DHS
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
--»
«--
Our Partner Sites: www.kaycoindia.com | www.suctionunit.com | www.kayorthopaedics.com
Copyright © 2004-05. All Rights Reserved.